Installation of Paper Machine Doctor Blade:
Most operational issues are related to incorrect or incomplete installation of the doctor blade. Doctor blade are precision mechanical equipment that require great attention to installation and condition adjustment.
1. When operating the doctor blade, be sure to follow the doctor blades's instructions. Special attention: Installing the doctor blade from the middle position of the doctor blade may cause damage to the doctor blade seat structure or doctor blade frame.
2. The positioning of the doctor blade bracket must strictly follow the manufacturer's drawings. Before positioning the bracket, detailed and accurate measurements must be taken to ensure that there is no place to interfere or hinder the operation and adjustment of the doctor blade after the bracket is installed.
3. After the bracket is installed, install the bearing on the shaft neck and let the bearing and doctor blade fall onto the bracket. Do not tighten the screws at this time, only slightly tighten them so that the doctor blade can move during adjustment.
4. The doctor blade must be installed in a convenient location for operation (lifting or replacing blades).
5. The measuring device should be installed inside the doctor blade rack.
After installing the doctor blade, a level gauge should be used to measure the horizontal position of the doctor blade. After reading the data each time, a thin gasket of appropriate thickness should be placed under the doctor blade to adjust it to the horizontal position. In some positions, it is also required to use an angle meter to determine the angle of the doctor blade.
Paper Machine Doctor Blade Maintenance:
Once it enters the maintenance period, the doctor blade is usually easily overlooked. But some simple daily maintenance can keep this device running efficiently and continuously.
1. The first very effective common practice is to frequently replace the doctor blades as needed. When the doctor blade wears out, the angle between it and the roller will change, thereby reducing the cleaning efficiency of the doctor blade. When the width of the doctor blade wears out by 6mm to 12mm, it needs to be replaced.
2. The second important component that needs attention is the doctor frame. Any damage to the scraper frame will affect the pressure between the doctor blade and the roller. Damaged doctor blade frames should be replaced in a timely manner.
3. During each inspection, the pressurization and swinging devices in operation should be carefully checked. When defects are found, repairs should be carried out.
One of the most effective ways to check for doctor blade problems is to visually inspect the doctor blades.
Although the doctor blade appears to be a simple piece of paper machine equipment with relatively low investment, its role is not insignificant. It can maintain the cleanliness of the paper machine rollers and fabrics (forming fabric, press felt, dryer fabric, etc.), extend the cleaning cycle and fabric service life of the paper machine, maintain normal operation of the paper machine and stable paper quality, and thus generate huge benefits. Of course, in order to achieve these goals, it is still necessary to invest effort in daily life, discover abnormalities in the doctor blade during inspections, arrange for timely handling, and keep the doctor blade in good working condition.