Pulp Beating Degree Tester
Beating degree tester is an instrument used to detect the degree of pulp beating, also known as tapping degree. The instrument is mainly used to measure the filtration rate of diluted pulp suspension and is a routine instrument in the laboratory of pulp and paper enterprises.
Testing Material of Beating Degree Tester
Plant fibers: wood pulp, bamboo pulp, straw pulp, cotton pulp, hemp pulp
Synthetic fibers: aramid fiber, PET fiber, PPS fiber, PAN fiber
Artificial fibers: Lyocell fiber, polyester fiber, ketoamine fiber
Inorganic fibers: glass fiber cotton, ceramic fiber cotton
Nanofibers: nanocellulose, nanocarbon tubes, graphene, nanoscale inorganic fibers
Technical Parameter
| Measurement range | (0~100) SR, adjustable calibration bottom hole |
| Result display method | Electronic data display |
| Test accuracy | 0.1SR |
| Test mode | Single beating degree test mode |
| Operation mode | Automatic release test |
| Sealing adjustment method | automatic locking sealing |
| Side tube adjustment | With a side tube adjustment knob, the remaining volume can be adjusted freely |
| Overflow outlet drainage time | 149 ± 1s |
| Remaining volume | (7.5~8.0) ml |
| Cone rising speed | 100 ± 10mm/s |
| Dimensions | 410 * 360 * 760mm |
| Weight | 25kg |
Pulp Beating Degree Tester
Beating degree tester is an instrument used to detect the degree of pulp beating, also known as tapping degree. The instrument is mainly used to measure the filtration rate of diluted pulp suspension and is a routine instrument in the laboratory of pulp and paper enterprises.
Testing Material of Beating Degree Tester
Plant fibers: wood pulp, bamboo pulp, straw pulp, cotton pulp, hemp pulp
Synthetic fibers: aramid fiber, PET fiber, PPS fiber, PAN fiber
Artificial fibers: Lyocell fiber, polyester fiber, ketoamine fiber
Inorganic fibers: glass fiber cotton, ceramic fiber cotton
Nanofibers: nanocellulose, nanocarbon tubes, graphene, nanoscale inorganic fibers
Technical Parameter
| Measurement range | (0~100) SR, adjustable calibration bottom hole |
| Result display method | Electronic data display |
| Test accuracy | 0.1SR |
| Test mode | Single beating degree test mode |
| Operation mode | Automatic release test |
| Sealing adjustment method | automatic locking sealing |
| Side tube adjustment | With a side tube adjustment knob, the remaining volume can be adjusted freely |
| Overflow outlet drainage time | 149 ± 1s |
| Remaining volume | (7.5~8.0) ml |
| Cone rising speed | 100 ± 10mm/s |
| Dimensions | 410 * 360 * 760mm |
| Weight | 25kg |